IBC & Layflat Control
Internal Bubble Cooling (IBC) is designed to automatically control and manage blower balance and increase cooling efficiency.
- Non-contact, ultrasonic IBC bubble control
- Precise layflat control
- Waste reduction during start-up and changeover
Another critical factor on from materials blend and extrusion control for the performance of a blown film line is the IBC (Internal Bubble Cooling), with integrated auto width control for the layflat.
Upgrading a line without IBC & Layflat Control, or a line with a dated simpler system can deliver significant performance benefits for any blown film line.
Maguire + Syncro offer SYibc, which is a convenient and effective package for IBC and automatic Layflat Control. A processor can upgrade as a standalone product or integrated as part of the program of modular upgrades for improving performance on a blown film line from Maguire + Syncro range of products.
To enable fast and accurate control of a layflat width the SYibc uses a triangulation of 3 non-contact ultrasonic sensors, with a separate calibration sensor to moderate for ambient conditions. This data provides constant readings to the IBC PLC control, and enables the IBC stepper-controlled valves to be precisely regulated for fast and consistent control of the internal bubble cooling airflow.
Upgrading your line with Maguire +Syncro SYibc can quickly deliver these core benefits:
- Improved control and increases production rates.
- Optimize layflat control to less than ± 2mm of target set for LayFlat width control.
- Increase internal cooling rates – increases production and process consistency.
- Edge trim and startup waste reduced – reducing materials costs.
- Reduce manual interventions and setup.
- Easier product changes and quicker setups and startups.
- SYibc applicable for all types of IBC die, EasyWidth for non IBC – compressed air dies.
- Temperature compensation manages 24-hour ambient fluctuations.
- Cost effective to deploy – typical return of investment within 12 months.
Ultrasonic Layflat Sensors
- Optional ultrasonic distance sensors.
- Mounted on top of cage where bubble is already formed.
- Controls automatic opening & closing of cage.
- Improved layflat width control to less than ± 2mm.
Ambient Temperature Control
- Ultrasonic sensor installed at a fixed distance.
- To control ambient temperature variations.
Ultrasonic Gap Sensors
- Mounted on bottom of the cage.
- Maintain distance between bubble and moving cage.
- Measure instant bubble dimension variation.
- To avoid deflation of bubble.
IBC Control Valve
- Unique bypass valve to improve flow control.
- Valve installed on T pipe.
- Improved accuracy in bubble stability.
- Customized stepper motor.
Maguire + Syncro Control Flexibility
- Convenient operation and analysis via Syntrol Plus Supervisory System.
- Rapid detection and response for optimum width stabilization.
- Waste reduction.
- Improved bubble stability.
- Faster and simplified operator control.
- Possibility to store all key process setup parameters.